{"id":37,"date":"2018-02-24T01:12:13","date_gmt":"2018-02-23T23:12:13","guid":{"rendered":"http:\/\/xn--lundstrm-c5a.com\/?page_id=37"},"modified":"2021-09-16T21:37:48","modified_gmt":"2021-09-16T19:37:48","slug":"installation-of-pl7-pro-on-64-bit-based-systems","status":"publish","type":"page","link":"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/","title":{"rendered":"Installation of PL7 Pro on 64-bit based systems"},"content":{"rendered":"<h1>Files needed<\/h1>\n<p>PL7 Pro installation media &#8211; Too big for online scan &#8211; <a href=\"https:\/\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/03\/PL7_Installation.zip\">Download<\/a><\/p>\n<p>setup32.exe &#8211; <a href=\"https:\/\/www.virustotal.com\/da\/file\/b5cb728d54185aeb94d58d69968e4fc8b20f4f8e09f4919813ecf0aa2a1bc1f0\/analysis\/1519407903\/\">Virus scan result<\/a> &#8211; <a href=\"https:\/\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/setup32.zip\">Download<\/a><\/p>\n<p>Unitelway_driver_7_2_2019-.zip &#8211; <a href=\"https:\/\/www.virustotal.com\/#\/file\/2cca34b64bca9841fa86609ee9c5bd8b9d449ac415a196eaf0e670ecd4a040ec\/detection\">Virus scan result<\/a> &#8211; <a href=\"http:\/\/lundstr\u00f8m.com\/wp-content\/uploads\/2019\/02\/Unitelway_driver_7_2_2019-.zip\">Download<\/a>\u00a0&#8211; <span style=\"color: #ff0000;\">Please do not use an older driver as they tend to mess things up<\/span><\/p>\n<p><strong>Optional:<\/strong><\/p>\n<p>PL7 Pro SP5 &#8211; Too big for online scan &#8211; <a href=\"https:\/\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/03\/PL7V45SP5.zip\">Download<\/a><\/p>\n<p>Enabledlinkedconnections.reg &#8211; <a href=\"https:\/\/www.virustotal.com\/da\/file\/e7fcb351608a46e54c2ec82ef5139737952b312fbd93b2111b22ee6f4c278517\/analysis\/1519410910\/\">Virus scan result<\/a>\u00a0&#8211; <a href=\"https:\/\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/03\/Enablelinkedconnections.zip\">Download<\/a><\/p>\n<p>XIP-driver_7_2_2019.zip &#8211; <a href=\"https:\/\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/02\/XIP-driver_7_2_2019.zip\">Download<\/a>\u00a0&#8211; Useful if you have an ethernet enabled PLC<\/p>\n<h1><\/h1>\n<h1>Introduction<\/h1>\n<p>Unfortunately Schneider Electric has decided not to support PL7 on 64-bit systems, it can also be difficult to get PL7 to work on later versions of windows.<br \/>\nTheir official response is &#8216;Upgrade to Unity, convert your program&#8217; but this is really not an option on a running system that just need a minor update or maintenance.<\/p>\n<p>This guide will show you how to install PL7 Pro\u00a0<strong>natively\u00a0<\/strong>in Windows 10 x64 &#8211; this is done without the use of virtual machines.<\/p>\n<p>It has been tested to work with the TSXCUSB485 USB cable and the TSXPCX1031 RS232 cable.<br \/>\nThe RS232 cable is easier to work with as it does not require an additional driver like the USB cable does.<\/p>\n<p>if your laptop does not have a RS232 port as pretty much all newer models do, you&#8217;ve probably tried a USB to serial converter, 9 out of 10 times this does not work.<br \/>\nThrough trial and error I&#8217;ve found that the <a href=\"https:\/\/www.startech.com\/Cards-Adapters\/Serial-Cards-Adapters\/1-Port-USB-Serial-RS232-Adapter-Cable~ICUSB2321F\">StarTech\u00a0ICUSB2321F<\/a> works flawlessly, so give it a try if you have serial programming cables lying around.<\/p>\n<p>With the latest XIP driver from Schneider, it is also possible to program via the XIP driver<\/p>\n<p>Please follow the steps carefully, it is quite difficult to recover from a botched driver installation, as it is almost impossible to uninstall the wrong driver version, and previous version won&#8217;t install if a later version is present on the system.<\/p>\n<h1>Step 1 &#8211; Preparing to install PL7 Pro<\/h1>\n<p>Copy the contents of the CD-ROM to a directory on your harddrive, for example C:\\PL7 Installation<br \/>\nI recommend <strong>NOT\u00a0<\/strong>putting it in C:\\PL7 as this is the default installation dir for PL7.<\/p>\n<p>Next, unzip <a href=\"http:\/\/lundstr\u00f8m.com\/wp-content\/uploads\/2018\/02\/setup32.zip\">setup32.zip<\/a> and place setup32.exe into the installation dir<br \/>\nIt should look something like this:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Step1.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"46\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/step1\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Step1.png?fit=597%2C333&amp;ssl=1\" data-orig-size=\"597,333\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"File explorer\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Step1.png?fit=597%2C333&amp;ssl=1\" class=\"alignnone size-full wp-image-46\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Step1.png?resize=597%2C333\" alt=\"\" width=\"597\" height=\"333\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Step1.png?w=597&amp;ssl=1 597w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Step1.png?resize=300%2C167&amp;ssl=1 300w\" sizes=\"auto, (max-width: 597px) 100vw, 597px\" \/><\/a><\/p>\n<p>If you run setup.exe like you&#8217;re supposed to, you&#8217;ll get this error:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/bad_format.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"45\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/bad_format\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/bad_format.png?fit=205%2C147&amp;ssl=1\" data-orig-size=\"205,147\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Bad format\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/bad_format.png?fit=205%2C147&amp;ssl=1\" class=\"alignnone size-full wp-image-45\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/bad_format.png?resize=205%2C147\" alt=\"\" width=\"205\" height=\"147\" \/><\/a><\/p>\n<p>This has usually been the showstopper for installing PL7 Pro on any 64-bit based system.<\/p>\n<p>However if you run setup32.exe the installation will start up correctly:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"47\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install1\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?fit=1920%2C1080&amp;ssl=1\" data-orig-size=\"1920,1080\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 1\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?fit=665%2C374&amp;ssl=1\" class=\"alignnone size-large wp-image-47\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1-1024x576.png?resize=665%2C374\" alt=\"\" width=\"665\" height=\"374\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?resize=1024%2C576&amp;ssl=1 1024w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?resize=300%2C169&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?resize=768%2C432&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?resize=660%2C371&amp;ssl=1 660w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?w=1920&amp;ssl=1 1920w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install1.png?w=1330&amp;ssl=1 1330w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><\/a><\/p>\n<p>Follow the installation like you normally would by pressing next:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install2.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"48\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install2\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install2.png?fit=509%2C363&amp;ssl=1\" data-orig-size=\"509,363\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 2\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install2.png?fit=509%2C363&amp;ssl=1\" class=\"alignnone size-full wp-image-48\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install2.png?resize=509%2C363\" alt=\"\" width=\"509\" height=\"363\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install2.png?w=509&amp;ssl=1 509w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install2.png?resize=300%2C214&amp;ssl=1 300w\" sizes=\"auto, (max-width: 509px) 100vw, 509px\" \/><\/a><\/p>\n<p>I select english and press Next &gt; &gt;<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install3.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"49\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install3\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install3.png?fit=494%2C354&amp;ssl=1\" data-orig-size=\"494,354\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 3\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install3.png?fit=494%2C354&amp;ssl=1\" class=\"alignnone size-full wp-image-49\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install3.png?resize=494%2C354\" alt=\"\" width=\"494\" height=\"354\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install3.png?w=494&amp;ssl=1 494w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install3.png?resize=300%2C215&amp;ssl=1 300w\" sizes=\"auto, (max-width: 494px) 100vw, 494px\" \/><\/a><\/p>\n<p>Insert your installation code, it is usually located on a sticker placed on the jewel case of your installation CD, and press OK.<br \/>\n<strong>I cannot give you a code, you must obtain one from Schneider Electric.<\/strong><\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install4.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"50\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install4\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install4.png?fit=497%2C355&amp;ssl=1\" data-orig-size=\"497,355\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 4\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install4.png?fit=497%2C355&amp;ssl=1\" class=\"alignnone size-full wp-image-50\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install4.png?resize=497%2C355\" alt=\"\" width=\"497\" height=\"355\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install4.png?w=497&amp;ssl=1 497w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install4.png?resize=300%2C214&amp;ssl=1 300w\" sizes=\"auto, (max-width: 497px) 100vw, 497px\" \/><\/a><\/p>\n<p>Type in your name and company, you must type something in both fields, otherwise Next &gt; &gt; will be greyed out.<br \/>\nPress Next &gt; when you&#8217;ve filled out both fields.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install5.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"51\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install5\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install5.png?fit=491%2C346&amp;ssl=1\" data-orig-size=\"491,346\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 5\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install5.png?fit=491%2C346&amp;ssl=1\" class=\"alignnone size-full wp-image-51\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install5.png?resize=491%2C346\" alt=\"\" width=\"491\" height=\"346\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install5.png?w=491&amp;ssl=1 491w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install5.png?resize=300%2C211&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install5.png?resize=200%2C140&amp;ssl=1 200w\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" \/><\/a><\/p>\n<p>I select &#8216;Standard installation&#8217; and press Next &gt;<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install6.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"53\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install6\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install6.png?fit=496%2C354&amp;ssl=1\" data-orig-size=\"496,354\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 6\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install6.png?fit=496%2C354&amp;ssl=1\" class=\"alignnone size-full wp-image-53\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install6.png?resize=496%2C354\" alt=\"\" width=\"496\" height=\"354\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install6.png?w=496&amp;ssl=1 496w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install6.png?resize=300%2C214&amp;ssl=1 300w\" sizes=\"auto, (max-width: 496px) 100vw, 496px\" \/><\/a><\/p>\n<p>For the sake of simplicity I recommend that you install it into the default directory &#8211; Just press Next &gt;<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install7.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"54\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install7\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install7.png?fit=518%2C350&amp;ssl=1\" data-orig-size=\"518,350\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 7\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install7.png?fit=518%2C350&amp;ssl=1\" class=\"alignnone size-full wp-image-54\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install7.png?resize=518%2C350\" alt=\"\" width=\"518\" height=\"350\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install7.png?w=518&amp;ssl=1 518w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install7.png?resize=300%2C203&amp;ssl=1 300w\" sizes=\"auto, (max-width: 518px) 100vw, 518px\" \/><\/a><\/p>\n<p>This is a summary, if you are ready to install press Next &gt;<br \/>\nThe installation will now run, first it will install PL7, then it will attempt to install the Unitelway Driver.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install8.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"55\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/install8\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install8.png?fit=499%2C350&amp;ssl=1\" data-orig-size=\"499,350\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 installation step 8\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install8.png?fit=499%2C350&amp;ssl=1\" class=\"alignnone size-full wp-image-55\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install8.png?resize=499%2C350\" alt=\"\" width=\"499\" height=\"350\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install8.png?w=499&amp;ssl=1 499w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install8.png?resize=300%2C210&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/install8.png?resize=200%2C140&amp;ssl=1 200w\" sizes=\"auto, (max-width: 499px) 100vw, 499px\" \/><\/a><\/p>\n<p>The installation will complain that &#8216;A minor error occured&#8217; this is normal, don&#8217;t worry about it, now click &#8216;Return to Windows&#8217;<\/p>\n<p>The installation will create a folder called\u00a0 &#8216;Modicon Telemecanique&#8217; if you look in the start menu of windows. It will contain a non-working drivers manager &#8211; we&#8217;ll fix this later.<\/p>\n<p>It failed at creating the shortcut for PL7 and we will have to create that manually<\/p>\n<p>Open up your file explorer and go to\u00a0C:\\PL7\\PL7PRO45\\EXE\\<\/p>\n<p>Find pl7pro.exe and rightclick it, go to &#8216;Send to&#8217; and select &#8216;Desktop (create shortcut)<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/createshortcut.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"56\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/createshortcut\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/createshortcut.png?fit=666%2C620&amp;ssl=1\" data-orig-size=\"666,620\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Create shortcut\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/createshortcut.png?fit=665%2C619&amp;ssl=1\" class=\"alignnone size-full wp-image-56\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/createshortcut.png?resize=665%2C619\" alt=\"\" width=\"665\" height=\"619\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/createshortcut.png?w=666&amp;ssl=1 666w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/createshortcut.png?resize=300%2C279&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/createshortcut.png?resize=660%2C614&amp;ssl=1 660w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><\/a><\/p>\n<p>This will create a shortcut to PL7 Pro on your desktop:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/pl7shortcut.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"57\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/pl7shortcut\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/pl7shortcut.png?fit=116%2C66&amp;ssl=1\" data-orig-size=\"116,66\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"PL7 Pro shortcut\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/pl7shortcut.png?fit=116%2C66&amp;ssl=1\" class=\"alignnone size-full wp-image-57\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/pl7shortcut.png?resize=116%2C66\" alt=\"\" width=\"116\" height=\"66\" \/><\/a><\/p>\n<p>In order to run PL7 properly you must run it as administrator, failure to do so will result in a licens alias file error.<br \/>\nYou do not have to run PL7 at this time, if you install service pack 5 it will automatically request administrator access, and you won&#8217;t have to set it up manually.<\/p>\n<p>This concludes step 1, and the PL7 Pro application itself should now be running natively in 64-bit windows.<\/p>\n<h1>Step 2 &#8211; Installation of Service Pack 5<\/h1>\n<p>This step is very similar to step 1.<br \/>\nIf you&#8217;re logged into\u00a0<a href=\"http:\/\/www.tscautomate.com\">http:\/\/www.tscautomate.com<\/a>\u00a0with your credentials the direct link for Service Pack 5 is\u00a0<a href=\"http:\/\/www.tscautomate.com\/files\/5\/8\/0\/3\/pl7v45sp5.zip\">http:\/\/www.tscautomate.com\/files\/5\/8\/0\/3\/pl7v45sp5.zip<\/a><br \/>\nIf you&#8217;re not logged in you&#8217;ll get an error message stating &#8220;Access denied. You&#8217;re not logged.&#8221;<br \/>\nDon&#8217;t worry if you do not have access to tscautomate.com, you can download it from my page <a href=\"http:\/\/lundstr\u00f8m.com\/wp-content\/uploads\/2018\/03\/PL7V45SP5.zip\">here<\/a><br \/>\nUnzip\u00a0pl7v45sp5.zip to a directory on your PC; I used C:\\PL7V45SP5 which\u00a0 is the default directory in the zip file.<br \/>\nCopy the same setup32.exe you used for the PL7 installation to your Service Pack 5 directory.<br \/>\nIt should look something like this:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5step1.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"60\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/sp5step1\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5step1.png?fit=600%2C360&amp;ssl=1\" data-orig-size=\"600,360\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Service pack 5 step 1\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5step1.png?fit=600%2C360&amp;ssl=1\" class=\"alignnone size-full wp-image-60\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5step1.png?resize=600%2C360\" alt=\"\" width=\"600\" height=\"360\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5step1.png?w=600&amp;ssl=1 600w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5step1.png?resize=300%2C180&amp;ssl=1 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<p>Now run setup32.exe, the installation should now start correctly:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"61\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/sp5\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?fit=1920%2C1080&amp;ssl=1\" data-orig-size=\"1920,1080\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Service Pack 5 install screen\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?fit=665%2C374&amp;ssl=1\" class=\"alignnone size-large wp-image-61\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5-1024x576.png?resize=665%2C374\" alt=\"\" width=\"665\" height=\"374\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?resize=1024%2C576&amp;ssl=1 1024w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?resize=300%2C169&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?resize=768%2C432&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?resize=660%2C371&amp;ssl=1 660w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?w=1920&amp;ssl=1 1920w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp5.png?w=1330&amp;ssl=1 1330w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><\/a><\/p>\n<p>Select Next &gt; &gt;<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp52.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"62\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/sp52\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp52.png?fit=509%2C363&amp;ssl=1\" data-orig-size=\"509,363\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"sp52\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp52.png?fit=509%2C363&amp;ssl=1\" class=\"alignnone size-full wp-image-62\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp52.png?resize=509%2C363\" alt=\"\" width=\"509\" height=\"363\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp52.png?w=509&amp;ssl=1 509w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp52.png?resize=300%2C214&amp;ssl=1 300w\" sizes=\"auto, (max-width: 509px) 100vw, 509px\" \/><\/a><\/p>\n<p>Once again, select language, I choose english, when you&#8217;re done click Next &gt; &gt;<br \/>\nInstallation should now begin.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp53.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"63\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/sp53\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp53.png?fit=496%2C232&amp;ssl=1\" data-orig-size=\"496,232\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Service Pack 5 installation step 3\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp53.png?fit=496%2C232&amp;ssl=1\" class=\"alignnone size-full wp-image-63\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp53.png?resize=496%2C232\" alt=\"\" width=\"496\" height=\"232\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp53.png?w=496&amp;ssl=1 496w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp53.png?resize=300%2C140&amp;ssl=1 300w\" sizes=\"auto, (max-width: 496px) 100vw, 496px\" \/><\/a><\/p>\n<p>This page will pop up during the installation process, I choose &#8220;Install&#8221;, but you can probably get away with choosing &#8220;Don&#8217;t Install&#8221;, I haven&#8217;t tested it this way though.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp54.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"64\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/sp54\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp54.png?fit=500%2C355&amp;ssl=1\" data-orig-size=\"500,355\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Service Pack 5 installation step 4\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp54.png?fit=500%2C355&amp;ssl=1\" class=\"alignnone size-full wp-image-64\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp54.png?resize=500%2C355\" alt=\"\" width=\"500\" height=\"355\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp54.png?w=500&amp;ssl=1 500w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/sp54.png?resize=300%2C213&amp;ssl=1 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<p>Installation complete &#8211; click Return to Windows.<br \/>\nIt is not necessary to reboot, this won&#8217;t make the drivers manager work regardless.<\/p>\n<p>This concludes the service pack 5 installation.<\/p>\n<h1>Step 3 &#8211; Getting the drivers manager to work<\/h1>\n<p>Download the Unitelway Drivers Suite from this page: <a href=\"http:\/\/lundstr\u00f8m.com\/wp-content\/uploads\/2019\/02\/Unitelway_driver_7_2_2019-.zip\">Download<\/a><br \/>\n<span style=\"color: #ff0000;\">!PLEASE DO NOT USE OLDER DRIVERS AS THEY CAN MESS UP YOUR INSTALLATION!<\/span><\/p>\n<p>It contains a directory with the release notes and the installation file, I just unzipped it on my desktop.<br \/>\nRun the extracted file\u00a0SchneiderUnitelwayDriverSuite.exe it will request adminstrator privileges, answer yes.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway1.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"67\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/unitelway1\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway1.png?fit=400%2C147&amp;ssl=1\" data-orig-size=\"400,147\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Unitelway installation step 1\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway1.png?fit=400%2C147&amp;ssl=1\" class=\"alignnone size-full wp-image-67\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway1.png?resize=400%2C147\" alt=\"\" width=\"400\" height=\"147\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway1.png?w=400&amp;ssl=1 400w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway1.png?resize=300%2C110&amp;ssl=1 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<p>When the installation starts it will ask you to upgrade the drivers manager, answer yes here.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway2.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"68\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/unitelway2\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway2.png?fit=409%2C147&amp;ssl=1\" data-orig-size=\"409,147\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Unitelway installation step 2\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway2.png?fit=409%2C147&amp;ssl=1\" class=\"alignnone size-full wp-image-68\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway2.png?resize=409%2C147\" alt=\"\" width=\"409\" height=\"147\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway2.png?w=409&amp;ssl=1 409w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Unitelway2.png?resize=300%2C108&amp;ssl=1 300w\" sizes=\"auto, (max-width: 409px) 100vw, 409px\" \/><\/a><\/p>\n<p>Later it will ask you to upgrade &#8216;Unitelway Driver X64&#8217;, answer yes here.<\/p>\n<p>Give it some time, and when no more installation windows are active in the windows taskbar, the new drivers manager should be installed.<br \/>\nIf you can&#8217;t find it try looking in the windows control panel.<br \/>\n<a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/controlpanel.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"69\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/controlpanel\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/controlpanel.png?fit=177%2C48&amp;ssl=1\" data-orig-size=\"177,48\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Drivers manager in the control panel\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/controlpanel.png?fit=177%2C48&amp;ssl=1\" class=\"alignnone size-full wp-image-69\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/controlpanel.png?resize=177%2C48\" alt=\"\" width=\"177\" height=\"48\" \/><\/a><\/p>\n<p>The icon and text looks like this in Windows 10<\/p>\n<p>Double click the drivers manager to activate it, if all things work as they should it should open like this:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"70\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/driversmanager\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager.png?fit=457%2C290&amp;ssl=1\" data-orig-size=\"457,290\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Driversmanager\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager.png?fit=457%2C290&amp;ssl=1\" class=\"alignnone size-full wp-image-70\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager.png?resize=457%2C290\" alt=\"\" width=\"457\" height=\"290\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager.png?w=457&amp;ssl=1 457w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager.png?resize=300%2C190&amp;ssl=1 300w\" sizes=\"auto, (max-width: 457px) 100vw, 457px\" \/><\/a><\/p>\n<p>Selecting the &#8216;UNITELWAY Driver&#8217; tab should open a page like this:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager2.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"71\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/driversmanager2\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager2.png?fit=457%2C290&amp;ssl=1\" data-orig-size=\"457,290\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Driversmanager &amp;#8211; UNITELWAY\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager2.png?fit=457%2C290&amp;ssl=1\" class=\"alignnone size-full wp-image-71\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager2.png?resize=457%2C290\" alt=\"\" width=\"457\" height=\"290\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager2.png?w=457&amp;ssl=1 457w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager2.png?resize=300%2C190&amp;ssl=1 300w\" sizes=\"auto, (max-width: 457px) 100vw, 457px\" \/><\/a><\/p>\n<p>Selecting &#8216;Configuration&#8217; will cause CnfUTW3.exe to request administrator privileges, selecting yes should open this page:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager3.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"72\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/driversmanager3\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager3.png?fit=460%2C338&amp;ssl=1\" data-orig-size=\"460,338\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Driversmanager &amp;#8211; UNITELWAY driver 2\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager3.png?fit=460%2C338&amp;ssl=1\" class=\"alignnone size-full wp-image-72\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager3.png?resize=460%2C338\" alt=\"\" width=\"460\" height=\"338\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager3.png?w=460&amp;ssl=1 460w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager3.png?resize=300%2C220&amp;ssl=1 300w\" sizes=\"auto, (max-width: 460px) 100vw, 460px\" \/><\/a><\/p>\n<p>Highlighting the (Default) Station identifier and selecting &#8216;Edit&#8230;&#8217; should open this page:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager4.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"73\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/driversmanager4\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager4.png?fit=331%2C454&amp;ssl=1\" data-orig-size=\"331,454\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Driversmanager &amp;#8211; COM settings\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager4.png?fit=331%2C454&amp;ssl=1\" class=\"alignnone size-full wp-image-73\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager4.png?resize=331%2C454\" alt=\"\" width=\"331\" height=\"454\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager4.png?w=331&amp;ssl=1 331w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/Driversmanager4.png?resize=219%2C300&amp;ssl=1 219w\" sizes=\"auto, (max-width: 331px) 100vw, 331px\" \/><\/a><\/p>\n<p>If you are using a RS232 cable select the right COM port, you need to know what your port is called as there is no indication what port the cable is installed on.<\/p>\n<p>If the USB cable driver is installed correctly and the cable is attached you should see (ready) after the COM port it is installed on in the drop down list.<\/p>\n<p>If the USB cable is NOT showing up correctly you may need an update Unitelway driver as it also contains the windows driver for the USB cable (Check <a href=\"http:\/\/tscautomate.com\">http:\/\/tscautomate.com<\/a> for updates if it suddenly stops working, I will also try to post new drivers on the front of this blog).<\/p>\n<p>You can check the windows device manager to see if the USB driver is installed properly, if you have a yellow exclamation mark next to it you probably need a driver update.<\/p>\n<p>This concludes the drivers manager installation, you should now have a working PL7 Pro installation with SP5 installed and the ability to connect to a PLC and program it via the USB or Serial cable.<\/p>\n<h1>Step 4 &#8211; Enabling the ability to open .stx files directly from network shares<\/h1>\n<p>If you are having trouble opening .stx files directly on a network drive then you may need this small fix.<br \/>\nThis is not really a PL7 issue but more of a windows quirk.<\/p>\n<p>Download <a href=\"http:\/\/lundstr\u00f8m.com\/wp-content\/uploads\/2018\/03\/Enablelinkedconnections.zip\">Enabledlinkedconnections.zip<\/a><br \/>\nUnzip the file\u00a0Enablelinkedconnections.reg somewhere, I would choose my windows desktop<br \/>\nRun\u00a0Enablelinkedconnections.reg<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"77\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/warning\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning.png?fit=466%2C344&amp;ssl=1\" data-orig-size=\"466,344\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Windows security warning\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning.png?fit=466%2C344&amp;ssl=1\" class=\"alignnone size-full wp-image-77\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning.png?resize=466%2C344\" alt=\"\" width=\"466\" height=\"344\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning.png?w=466&amp;ssl=1 466w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning.png?resize=300%2C221&amp;ssl=1 300w\" sizes=\"auto, (max-width: 466px) 100vw, 466px\" \/><\/a><\/p>\n<p>Just select &#8216;Run&#8217; here<\/p>\n<p>Windows will then ask you this:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning2.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"78\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/warning2\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning2.png?fit=558%2C178&amp;ssl=1\" data-orig-size=\"558,178\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Windows security warning 2\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning2.png?fit=558%2C178&amp;ssl=1\" class=\"alignnone size-full wp-image-78\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning2.png?resize=558%2C178\" alt=\"\" width=\"558\" height=\"178\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning2.png?w=558&amp;ssl=1 558w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2018\/02\/warning2.png?resize=300%2C96&amp;ssl=1 300w\" sizes=\"auto, (max-width: 558px) 100vw, 558px\" \/><\/a><\/p>\n<p>Select yes here to merge the file with the registry database.<br \/>\nIf you feel unsafe opening a .reg file you can simply open the .reg file with notepad and add the settings manually, it&#8217;s just 1 setting:<\/p>\n<p>[HKEY_LOCAL_MACHINE\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Policies\\System]<br \/>\n&#8220;EnableLinkedConnections&#8221;=dword:00000001<\/p>\n<p>Reboot your PC and it should work.<\/p>\n<p>This concludes step 4<\/p>\n<h1>Step 5 &#8211; Installation of the XIP driver<\/h1>\n<p>The XIP driver is used to transfer program via ethernet to premium PLCs with an ethernet port onboard (For example <a href=\"https:\/\/www.schneider-electric.us\/en\/product\/TSXP573623AM\/double-format-pl7-processor---transparent-ready---1360-ma\/\">TSX P573623A<\/a>)<br \/>\nThis method is <strong>MUCH FASTER<\/strong> than via the serial cable.<br \/>\nThis step is <strong>OPTIONAL<\/strong> if you do not intend to program via an ethernet cable, you can skip this part.<br \/>\nHowever, a valid ethernet configuration must already be on the PLC, meaning you cannot program an empty card with this method, for that you must still use the serial cable.<br \/>\nPersonally, I have a small program with just a hardware configuration that contains just an ethernet setup and nothing else.<br \/>\nI download this to the PLC via the serial cable, and when the download is complete and the ethernet module is initialized, I download the large program via the ethernet cable.<\/p>\n<p>Download the XIP driver suite from here: <a href=\"http:\/\/lundstr\u00f8m.com\/wp-content\/uploads\/2019\/02\/XIP-driver_7_2_2019.zip\">Download<\/a><br \/>\nExtract the contents, it should contain a directory called &#8216;XIP driver&#8217; with the release notes and the executable for installation.<\/p>\n<p>Run &#8216;SchneiderXipDriverSuite.exe&#8217;<\/p>\n<p>Follow the installation and when it is completed start &#8216;Driver manager&#8217; again<\/p>\n<p>Select the &#8216;XIP driver&#8217; tab:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP1.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"126\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip1\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP1.png?fit=685%2C510&amp;ssl=1\" data-orig-size=\"685,510\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Xip installation step 1\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP1.png?fit=665%2C495&amp;ssl=1\" class=\"alignnone wp-image-126\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP1.png?resize=464%2C346\" alt=\"\" width=\"464\" height=\"346\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP1.png?w=685&amp;ssl=1 685w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP1.png?resize=300%2C223&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP1.png?resize=660%2C491&amp;ssl=1 660w\" sizes=\"auto, (max-width: 464px) 100vw, 464px\" \/><\/a><\/p>\n<p>Click &#8216;Configuration&#8217;:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"127\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip2\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png?fit=773%2C695&amp;ssl=1\" data-orig-size=\"773,695\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 2\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png?fit=665%2C598&amp;ssl=1\" class=\"alignnone wp-image-127\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png?resize=549%2C494\" alt=\"\" width=\"549\" height=\"494\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png?w=773&amp;ssl=1 773w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png?resize=300%2C270&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png?resize=768%2C691&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP2.png?resize=660%2C593&amp;ssl=1 660w\" sizes=\"auto, (max-width: 549px) 100vw, 549px\" \/><\/a><\/p>\n<p>This screen should reflect the hardware setup in your PLC.<\/p>\n<p>To check theese things open your PL7 program in PL7 Pro:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"128\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip3\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png?fit=854%2C484&amp;ssl=1\" data-orig-size=\"854,484\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 3\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png?fit=665%2C377&amp;ssl=1\" class=\"alignnone wp-image-128\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png?resize=626%2C355\" alt=\"\" width=\"626\" height=\"355\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png?w=854&amp;ssl=1 854w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png?resize=300%2C170&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png?resize=768%2C435&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP3.png?resize=660%2C374&amp;ssl=1 660w\" sizes=\"auto, (max-width: 626px) 100vw, 626px\" \/><\/a><\/p>\n<p>Double click the hardware configuration in the application browser:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"129\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip4\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png?fit=798%2C821&amp;ssl=1\" data-orig-size=\"798,821\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP Installation 4\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png?fit=665%2C684&amp;ssl=1\" class=\"alignnone wp-image-129\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png?resize=627%2C645\" alt=\"\" width=\"627\" height=\"645\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png?w=798&amp;ssl=1 798w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png?resize=292%2C300&amp;ssl=1 292w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png?resize=768%2C790&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP4.png?resize=660%2C679&amp;ssl=1 660w\" sizes=\"auto, (max-width: 627px) 100vw, 627px\" \/><\/a><\/p>\n<p>Double click the &#8216;ETY PORT&#8217; slot:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"130\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip5\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?fit=1118%2C777&amp;ssl=1\" data-orig-size=\"1118,777\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 5\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?fit=665%2C462&amp;ssl=1\" class=\"alignnone size-large wp-image-130\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5-1024x712.png?resize=665%2C462\" alt=\"\" width=\"665\" height=\"462\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?resize=1024%2C712&amp;ssl=1 1024w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?resize=300%2C208&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?resize=768%2C534&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?resize=660%2C459&amp;ssl=1 660w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?resize=200%2C140&amp;ssl=1 200w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP5.png?w=1118&amp;ssl=1 1118w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><\/a><\/p>\n<p>The info you need is the &#8216;XWAY address&#8217; and the &#8216;IP address&#8217;<\/p>\n<p>Go back to your XIP configuration:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"131\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip6\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png?fit=773%2C695&amp;ssl=1\" data-orig-size=\"773,695\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 6\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png?fit=665%2C598&amp;ssl=1\" class=\"alignnone wp-image-131\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png?resize=654%2C588\" alt=\"\" width=\"654\" height=\"588\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png?w=773&amp;ssl=1 773w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png?resize=300%2C270&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png?resize=768%2C691&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP6.png?resize=660%2C593&amp;ssl=1 660w\" sizes=\"auto, (max-width: 654px) 100vw, 654px\" \/><\/a><\/p>\n<p>Local host:<br \/>\nXWAY address: must be NETWORK.UnusedStationID.<br \/>\nIn this example where the PLC is on network 10 we must therefore start with 10 and since nothing is using station 63 this is a valid station number for the PC.<\/p>\n<p>New Remote host:<\/p>\n<p>Station: Can be whatever you want, I just call it Premium_PLC<br \/>\nXWAY address: Is what you noted in your hardware configuration, in this example 10.10<br \/>\nIP Address is the IP you noted for the PLC, in this example 10.0.0.104<\/p>\n<p>Click the &#8216;Add&#8217; Button:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"132\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip7\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png?fit=775%2C696&amp;ssl=1\" data-orig-size=\"775,696\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP7 installation part 7\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png?fit=665%2C597&amp;ssl=1\" class=\"alignnone wp-image-132\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png?resize=488%2C438\" alt=\"\" width=\"488\" height=\"438\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png?w=775&amp;ssl=1 775w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png?resize=300%2C269&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png?resize=768%2C690&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP7.png?resize=660%2C593&amp;ssl=1 660w\" sizes=\"auto, (max-width: 488px) 100vw, 488px\" \/><\/a><\/p>\n<p>When you press &#8216;Add&#8217; it shows up under &#8216;Remote hosts configured&#8217;<\/p>\n<p>Now go to Bind&#8230;:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"133\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip8\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png?fit=775%2C696&amp;ssl=1\" data-orig-size=\"775,696\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation Part 8\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png?fit=665%2C597&amp;ssl=1\" class=\"alignnone wp-image-133\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png?resize=486%2C437\" alt=\"\" width=\"486\" height=\"437\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png?w=775&amp;ssl=1 775w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png?resize=300%2C269&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png?resize=768%2C690&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP8.png?resize=660%2C593&amp;ssl=1 660w\" sizes=\"auto, (max-width: 486px) 100vw, 486px\" \/><\/a><\/p>\n<p>Select your ethernet adapter by clicking the drop down button:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP9.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"134\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip9\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP9.png?fit=635%2C229&amp;ssl=1\" data-orig-size=\"635,229\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 9\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP9.png?fit=635%2C229&amp;ssl=1\" class=\"alignnone wp-image-134\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP9.png?resize=491%2C177\" alt=\"\" width=\"491\" height=\"177\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP9.png?w=635&amp;ssl=1 635w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP9.png?resize=300%2C108&amp;ssl=1 300w\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" \/><\/a><\/p>\n<p>If your adapter is missing you can use the small up\/down arrows on the right to find it.<br \/>\nYou can also use the arrow keys on your keyboard.<br \/>\nREMEMBER: The chosen ethernet adapter MUST have a unique IP on the SAME SUBNET as the PLC<br \/>\nMeaning, for this example you could set a static IP on the specified ethernet adapter called 10.0.0.200 and subnet 255.255.255.0.<br \/>\nClick OK, when the adapter selection window closes press save:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"135\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip10\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png?fit=775%2C696&amp;ssl=1\" data-orig-size=\"775,696\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 10\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png?fit=665%2C597&amp;ssl=1\" class=\"alignnone wp-image-135\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png?resize=501%2C450\" alt=\"\" width=\"501\" height=\"450\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png?w=775&amp;ssl=1 775w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png?resize=300%2C269&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png?resize=768%2C690&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP10.png?resize=660%2C593&amp;ssl=1 660w\" sizes=\"auto, (max-width: 501px) 100vw, 501px\" \/><\/a><\/p>\n<p>Now go to XIP and press start:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"136\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip11\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png?fit=770%2C696&amp;ssl=1\" data-orig-size=\"770,696\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 11\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png?fit=665%2C601&amp;ssl=1\" class=\"alignnone wp-image-136\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png?resize=502%2C453\" alt=\"\" width=\"502\" height=\"453\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png?w=770&amp;ssl=1 770w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png?resize=300%2C271&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png?resize=768%2C694&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP11.png?resize=660%2C597&amp;ssl=1 660w\" sizes=\"auto, (max-width: 502px) 100vw, 502px\" \/><\/a><\/p>\n<p>Red light in bottom right corner of the window should turn green:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP12.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"137\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip12\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP12.png?fit=194%2C223&amp;ssl=1\" data-orig-size=\"194,223\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 12\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP12.png?fit=194%2C223&amp;ssl=1\" class=\"alignnone size-full wp-image-137\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP12.png?resize=194%2C223\" alt=\"\" width=\"194\" height=\"223\" \/><\/a><\/p>\n<p>Close the XIP configuration window, either by using the X in the top right corner of the window, or by going to Configuration &gt; Exit<br \/>\nIf it asks you to save configuration again, just press &#8216;Yes&#8217;<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP13.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"138\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip13\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP13.png?fit=685%2C510&amp;ssl=1\" data-orig-size=\"685,510\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP Installation part 13\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP13.png?fit=665%2C495&amp;ssl=1\" class=\"alignnone wp-image-138\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP13.png?resize=561%2C418\" alt=\"\" width=\"561\" height=\"418\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP13.png?w=685&amp;ssl=1 685w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP13.png?resize=300%2C223&amp;ssl=1 300w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP13.png?resize=660%2C491&amp;ssl=1 660w\" sizes=\"auto, (max-width: 561px) 100vw, 561px\" \/><\/a><\/p>\n<p>As you can see Driver 1 state is now &#8216;Running&#8217;<\/p>\n<p>Close the driver manager and go to PL7, Select PLC -&gt; Define PLC Address&#8230;<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"139\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip14\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png?fit=862%2C1380&amp;ssl=1\" data-orig-size=\"862,1380\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP14\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png?fit=640%2C1024&amp;ssl=1\" class=\"alignnone size-large wp-image-139\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14-640x1024.png?resize=640%2C1024\" alt=\"\" width=\"640\" height=\"1024\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png?resize=640%2C1024&amp;ssl=1 640w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png?resize=187%2C300&amp;ssl=1 187w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png?resize=768%2C1230&amp;ssl=1 768w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png?resize=660%2C1057&amp;ssl=1 660w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP14.png?w=862&amp;ssl=1 862w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/a><\/p>\n<p>This will open a new window &#8211; This is how it looks if you wish to use the Unitelway driver(Serial cable\/TSXCUSB485 cable)<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP15.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"140\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip15\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP15.png?fit=524%2C404&amp;ssl=1\" data-orig-size=\"524,404\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP15\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP15.png?fit=524%2C404&amp;ssl=1\" class=\"alignnone wp-image-140\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP15.png?resize=416%2C321\" alt=\"\" width=\"416\" height=\"321\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP15.png?w=524&amp;ssl=1 524w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP15.png?resize=300%2C231&amp;ssl=1 300w\" sizes=\"auto, (max-width: 416px) 100vw, 416px\" \/><\/a><\/p>\n<p>This is how it looks if you wish to use the XIP driver(Ethernet cable):<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP16.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"141\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip16\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP16.png?fit=532%2C406&amp;ssl=1\" data-orig-size=\"532,406\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP16\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP16.png?fit=532%2C406&amp;ssl=1\" class=\"alignnone size-full wp-image-141\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP16.png?resize=532%2C406\" alt=\"\" width=\"532\" height=\"406\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP16.png?w=532&amp;ssl=1 532w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP16.png?resize=300%2C229&amp;ssl=1 300w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><\/a><\/p>\n<p>If your PLC is *not* running with network and station ID 10 you must change the numbers in between { and } accordingly<\/p>\n<p>Press OK and hit connect, if you have setup everything correctly it should respond as usual.<\/p>\n<p>If you are experiencing problems try double clicking on the XIP driver icon in your systray:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP17.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"142\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip17\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP17.png?fit=303%2C120&amp;ssl=1\" data-orig-size=\"303,120\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 17\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP17.png?fit=303%2C120&amp;ssl=1\" class=\"alignnone size-full wp-image-142\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP17.png?resize=303%2C120\" alt=\"\" width=\"303\" height=\"120\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP17.png?w=303&amp;ssl=1 303w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP17.png?resize=300%2C119&amp;ssl=1 300w\" sizes=\"auto, (max-width: 303px) 100vw, 303px\" \/><\/a><\/p>\n<p>It should show something like this:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP18.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"143\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip18\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP18.png?fit=505%2C593&amp;ssl=1\" data-orig-size=\"505,593\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP Installation part 18\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP18.png?fit=505%2C593&amp;ssl=1\" class=\"alignnone size-full wp-image-143\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP18.png?resize=505%2C593\" alt=\"\" width=\"505\" height=\"593\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP18.png?w=505&amp;ssl=1 505w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP18.png?resize=255%2C300&amp;ssl=1 255w\" sizes=\"auto, (max-width: 505px) 100vw, 505px\" \/><\/a><\/p>\n<p>As you can see there is 1 connection, this is good, this means that the PLC is detected.<br \/>\nIf you click the plus(+)-sign next to the amount of connections you can get a more detailed view:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP19.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"144\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip19\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP19.png?fit=535%2C390&amp;ssl=1\" data-orig-size=\"535,390\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP19\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP19.png?fit=535%2C390&amp;ssl=1\" class=\"alignnone size-full wp-image-144\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP19.png?resize=535%2C390\" alt=\"\" width=\"535\" height=\"390\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP19.png?w=535&amp;ssl=1 535w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP19.png?resize=300%2C219&amp;ssl=1 300w\" sizes=\"auto, (max-width: 535px) 100vw, 535px\" \/><\/a><\/p>\n<p>This means that the XIP profile we configured and called &#8216;Premium_PLC&#8217; is responding and is connected, and all is fine.<\/p>\n<p>If you&#8217;re unable to connect and unable to see the configured PLC in this window, you might have a problem with your network setup or your PLC configuration.<\/p>\n<p>You can also ping a configured PLC:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP20.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"145\" data-permalink=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/xip20\/\" data-orig-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP20.png?fit=635%2C302&amp;ssl=1\" data-orig-size=\"635,302\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"XIP installation part 20\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP20.png?fit=635%2C302&amp;ssl=1\" class=\"alignnone size-full wp-image-145\" src=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP20.png?resize=635%2C302\" alt=\"\" width=\"635\" height=\"302\" srcset=\"https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP20.png?w=635&amp;ssl=1 635w, https:\/\/i0.wp.com\/xn--lundstrm-c5a.com\/wp-content\/uploads\/2019\/09\/XIP20.png?resize=300%2C143&amp;ssl=1 300w\" sizes=\"auto, (max-width: 635px) 100vw, 635px\" \/><\/a><\/p>\n<p>If it does not respond you should check the ethernet settings of the used NIC, it should have a static IP set in the same subnet as the PLC with a <strong>UNIQUE IP<\/strong><\/p>\n<p>If it does respond and are still unable to connect, check the network and station ID,<\/p>\n<p>This concludes the XIP driver installation.<\/p>\n<h1>Conclusion<\/h1>\n<p>I hope this guide was helpful to you, you should now have a working PL7 Pro installation on your 64-bit version of windows.<br \/>\nIf you feel something is unclear, or if you simply have some tips or better methods let me know, and I&#8217;ll update the guide.<br \/>\nYou can contact me at <a href=\"mailto:morten@imap.cc\">morten@imap.cc<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Files needed PL7 Pro installation media &#8211; Too big for online scan &#8211; Download setup32.exe &#8211; Virus scan result &#8211; Download Unitelway_driver_7_2_2019-.zip &#8211; Virus scan result &#8211; Download\u00a0&#8211; Please do not use an older driver as they tend to mess things up Optional: PL7 Pro SP5 &#8211; Too big for online scan &#8211; Download Enabledlinkedconnections.reg\u2026 <span class=\"read-more\"><a href=\"https:\/\/xn--lundstrm-c5a.com\/index.php\/plc\/installation-of-pl7-pro-on-64-bit-based-systems\/\">Read More &raquo;<\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":35,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"page-templates\/full-width.php","meta":{"jetpack_post_was_ever_published":false,"footnotes":""},"class_list":["post-37","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/P9h8le-B","jetpack_likes_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/pages\/37","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/comments?post=37"}],"version-history":[{"count":31,"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/pages\/37\/revisions"}],"predecessor-version":[{"id":225,"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/pages\/37\/revisions\/225"}],"up":[{"embeddable":true,"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/pages\/35"}],"wp:attachment":[{"href":"https:\/\/xn--lundstrm-c5a.com\/index.php\/wp-json\/wp\/v2\/media?parent=37"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}